Genome Sequencer FLX Instrument
|
→Capable of amplifying and sequencing a library
of DNA fragments in a massively parallel fashion, the Genome Sequencer
FLX System provides advanced tools for ultra-high-throughput
sequencing, including: the GS FLX Instrument and accessories; advanced
software to generate base calls and interpret raw reads; reagent kits
for library construction, clonal amplification, and sequencing.
The Genome Sequencer instrument is
the centerpiece of the Genome Sequencer FLX System. The fluidics
subsystem ensures accurate reagent dispensing. It consists of a
reagents cassette holding the reagent containers, a sipper manifold,
pumps, valves, and debubblers. The fluidics subsystem flows the
sequencing reagents across the wells of the PicoTiterPlate device, and
moves the spent reagents from the PicoTiterPlate device to the waste
receptacle.
The optics subsystem consists of a CCD camera and a camera controller.
The camera captures the light emitted in the wells of the
PicoTiterPlate device during each step of the sequencing cycle, and
sends the digital images to the computer subsystem for processing.
The complete sequencing workflow of the Genome Sequencer FLX System
comprises four main steps, leading from purified DNA to analyzed
results. These basic steps include:
- Generation of a single-stranded template DNA library
- Emulsion-based clonal amplification of the library
- Data generation via sequencing-by-synthesis
- Data analysis using different bioinformatics tool
↑Top | Learn
More..
|
|
§
|
NimbleGen MS 200 Microarray Scanner
|
→The NimbleGen MS 200 Microarray Scanner is the
first scanner optimized to unleash the full potential and capture the
complete picture from NimbleGen DNA microarrays. The MS 200 offers 2
micron resolution and heightened sensitivity to achieve high data
quality and confident results from high-density NimbleGen microarrays
of today and tomorrow. Critical to the the workflow, NimbleScan and
SignalMap software are included to analyze and view the high-quality
data from the MS 200. High-throughput genomics research is
now possible with the MS 200’s automated features, which are
specifically designed for the NimbleGen microarray workflow. Advanced
features such as a 48-slide autoloader, integrated barcode reader,
autofocus, and auto gain combine to offer walkaway automation;
↑Top | Learn More..
|
|
§
|
Multisizer™ 3 COULTER COUNTER®
|
→Using The Coulter Principle, also known as ESZ
(Electrical Sensing Zone Method), the Multisizer 3 COULTER COUNTER
provides number, volume, mass and surface area size distributions in
one measurement, with an overall sizing range of 0.4 µm to 1,200 µm.
Its response is unaffected by particle color, shape, composition or
refractive index.
The Coulter Principle is the absolute leading
technology in high resolution and accuracy and it is further enhanced
in the Multisizer 3 by using a Digital Pulse Processor (DPP). You will
get the ultra-high resolution, multiple channel analysis and accuracy
not provided by any other technology. It all makes the Multisizer 3
indispensable for any industrial or life science research project
involving sizing and/or counting. Equally a powerful tool for quality
control, it provides the analyst with a system which is easy to use,
yet so technologically advanced that it is able to solve most particle
sizing problems.
↑Top | Learn
More..
|
|
§
|
Agilent 2100 Bioanalyzer Desktop System
|
→Applications:
- DNA Solutions (sizing and quantitation)
- RNA Solutions for RNA integrity check
- RNA Integrity Number (RIN), to compare quality
- Protein detection in ng range: Fast and reproducible protein
sizing and quantification
- Protein detection in pg range: High sensitivity and QA/QC
applications
- Cell Fluorescence
↑Top | Learn
More..
|
|
§
|
HydroShear |
|
→HydroShear®
offers the simplest, most reproducible, and most controllable method
available for generating random DNA fragments. This software-driven
device uses hydrodynamic shearing forces to fragment DNA strands.
With the HydroShear®, virtually any source of DNA at
any concentration in volumes as small as 40μl can be randomly
fractured to within a two-fold size distribution. For instance, if the
desired target size is 2kb, the HydroShear® can be
calibrated to produce a distribution centered on 2kb with 90% of the
DNA falling between 1.3kb and 2.6kb – ideal for plasmid sequencing
libraries.
↑Top | Learn More..
|
|
§
|
Thermal Cycler (1 head)
|
→Features of the DNA Engine thermal cycler
Single-bay cycler accommodates over ten different Alpha™ sample
blocks, including independently controlled dual blocks. Temperature
Gradient capability employs dynamic ramping, guaranteeing consistent
hold times across all sample wells.
↑Top | Learn More..
|
|
§
|
Thermal Cycler (4 heads)
|
→MJResearch, Model PTC-240 Tetrad 2 DNA Engine
Peltier thermal cycler, The Tetrad 2 contains an onboard Pentium-class
computer that delivers an advanced graphical interface—ideal for
managing production-grade thermal cycling. Real-time displays of
block, sample and lid temperatures provide quality assurance that the
thermal cycler is performing as directed.
↑Top | Learn More..
|
|
§
|
Allegra® X-15R, Benchtop Centrifuge
|
→Beckman Coulter introduces the Allegra X-15R
benchtop centrifuge, providing fast separations and optimal recovery
in the large capacity four x 750ml rotor.
This new instrument spins the popular rotor at 5250g - said to be the
fastest speed available for this capacity, and also spins microplate
carriers.
Described as ideal for many applications, the Allegra X-15R
accommodates Beckman Coulter's exclusive adapters for direct
centrifugation of cell culture flasks, eliminating an entire step in
the cell culture process.
It also incorporates Aries smart
balance rotor technology, which not only automatically detects
imbalance, but also corrects it, enabling customers to complete their
runs even if the samples are not balanced.
↑Top | Learn
More..
|
|
§
|
Millipore direct-Q
|
→The Direct-Q 5 tap-fed water purification
system is designed for scientists who need 5 to 15 L of ultrapure
water per day. This compact, silent system produces up to 0.6 L/min of
ultrapure (Type I) water on demand, directly from potable tap water.
Direct-Q system performance characteristics are automatically
monitored by pressure, temperature and resistivity sensors, and are
clearly shown on the system's display, which also indicates when
routine maintenance should be performed.
Applications
- Culture Media
- Buffers
- Blanks or Standard Solutions
↑Top | Learn
More..
|
|
§
|
Tissuelyser
|
→The TissueLyser system is well-suited for
high-throughput sample disruption, providing highly reproducible
results in many downstream applications. These include RNA
purification from difficult-to-lyse animal tissues and plant tissues
and DNA purification from animal tissues. For RNA applications,
stabilization of freshly harvested tissues in RNAlater
RNA Stabilization Reagent effectively prevents RNA degradation during
disruption with the TissueLyser system.
↑Top | Learn
More..
|
|
|
Perchloric acid hood
|
→The Iroquois perchloric acid fume hood is
designed specifically for procedures using perchloric acid. Based on
the LA-series superstructure, it features a one-piece, cove-cornered
Type 316 stainless steel interior with integral work surface and
washdown system. Regular use of the washdown system cleanses the hood
interior of perchloric salts, which drain into a full-length sloped
trough contained in the work surface. Access to plumbing is through
exterior access panels only. Due to the extreme reactivity of
perchloric acid, this hood should be used FOR PERCHLORIC ACID ONLY.
Standard
features include:
- One-piece 16-gage Type 316 stainless steel
interior – coved corners welded to dished, reinforced countertop with
integral cupsink and full-length sloped trough; all surfaces are
polished to #4 finish
- High-volume washdown tube with remote control
cold water valve
- Two-piece Type 316 stainless steel baffle
system with adjustable upper and lower dampers to regulate lighter-
and heavier-than-air gases
- Side post electrical and plumbing knockouts –
on bias surface; in standard or ADA configuration
- Bypass grill with adjustable louvers to
control bypass air volume
- Full frame, Type 316 stainless steel vertical
sash with integral stainless steel finger pull
- Type 316 stainless steel sash guides, lower
airfoil, duct collar
- Sash/counterweight pulley system utilizing
four 2 ½”-diameter pulleys for one-finger sash movement; full-width
counterweight featuring “Tilt-Lock” for additional safety and
durability
↑Top | Learn More..
|
|
§
|
VersaFluor Fluorometer
|
|
→The VersaFluor
cuvette fluorometer is a fast and simple way to quantitate DNA, RNA,
and proteins, to detect apoptosis, and to perform reporter enzyme
assays with the high level of sensitivity and selectivity that
fluorescent detection offers. The VersaFluor is a flexible cuvette
fluorometer, featuring changeable filters for multiple excitation and
emission wavelengths. To order the appropriate filter for your
application, use the Filter Selection Guide. The VersaFluor
fluorometer is the only instrument needed to detect and quantitate DNA
from PCR amplification, restriction digests, and plasmid preps, to
quantitate apoptosis activity, and to assay the reporter enzymes
beta-glucuronidase (GUS) and beta-galactosidase.
↑Top | Learn
More..
|
|
GO to equipment album |